Manufacturer: Fujitsu | Model: M2949S | TD# 265115 |
Interface... Ultra SCSI-2 | Formatted Capacity... 9100 MB |
Cylinders | 5772 | Heads | 18 | Sectors | 196 |
Landing Zone | Max Cyl | Precomp | N/A | RWC Cyl | N/A |
Encoding Method | RLL8,9 | Xfer/Mb(async/sync) | 6/20 | MTBF (Hr X 1000) | 800 |
Form factor | 3.5" | Novell Y/N | N | Height | 1.62" |
Power | N/A | Power Consumption | 15W | Speed | 7200 |
Avg seek (ms) | 10 | Cache | 506k | Mfg. Warranty | 5 YRS |
Copyright ⌐ 1996, 1997 Tech Data Corporation
Configuration and Jumper Options
M2949SYU 3.5" SCSI HDD Setup
SCSI ID Jumper Settings CN4
ID No. | 1-2 | 3-4 | 5-6 |
0 | OFF | OFF | OFF |
1 | ON | OFF | OFF |
2 | OFF | ON | OFF |
3 | ON | ON | OFF |
4 | OFF | OFF | ON |
5 | ON | OFF | ON |
6 | OFF | ON | ON |
7 | ON | ON | ON |
Mode Settings through CHANGE DEFINITION Command
OPTION | FACTORY SETTING |
SCSI Level | SCSI-2 |
Unit Attention Report Mode | Reported |
Reselection Retry Count | Unlimited |
LED Display Condition | Active/Busy |
Reselection time-out delay | 250ms |
Spindle motor start delay time | 0 s |
CN6 Option Settings
PINS | DESCRIPTION | DEFAULT |
D (5-6) | Offline Diagnostic Mode | OFF = Normal Operation |
P (3-4) | SCSI bus parity checking | ON = parity enabled |
A (1-2) | Automatic Motor Start | ON = motor starts at power on |
CN7 External Selection
PINS | DESCRIPTION |
1-2 | Spindle Sync Signal |
3-4 | Disk Drive Reset |
5-6 | Write Protect |
7-8 | Termination |
[Main
Menu] [Hard
Drives] [Controllers] [Tape Drives] [Glossary]